Accident Summary Nr: 170591226 - Employee's fingers amputated by cut-off saw

Accident Summary Nr: 170591226 -- Report ID: 0950633 -- Event Date: 04/19/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
12595835507/10/199552110Squires Lumber Co Inc

Abstract: At approximately 11:30 a.m. on April 19, 1995, Employee #1 was using a Whirlwind underhung swing cut-off saw to cut Douglas fir 2 by 4s for a customer. His hand contacted the rotating saw blade, which amputated his middle, ring, and small fingers of his right hand to the first digits. The cut-off saw was guarded in accordance with provisions of T8CCR 4306 and Employee #1 was trained and experienced in the use of the saw. The employer maintains an effective injury and illness prevention program. No safety violations of T8CCR were cited.

Keywords: ROTATING PARTS, AMPUTATED, FINGER, EQUIPMENT OPERATOR, SAW, BLADE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 125958355 Hospitalized injury Amputation Sawing machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.