Accident Report Detail
Accident Summary Nr: 170566848 - Employee killed when excavation caves in
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 300362175 | 10/16/1996 | 1623 | 0 | Minn-Kota Excavating, Inc. |
Abstract: At approximately 3:15 p.m. on October 15, 1996, Employee #1, age 20, and two coworkers were repairing a water pipe in a 10 ft deep excavation. A large section of the west wall and a section of the south wall collapsed, completely burying Employee #1 under 1 1/2 to 2 feet of sand, and burying his coworkers to their waists. A backhoe operator working nearby began digging out the two standing coworkers while yelling to another coworker to call 911. When the buried men were freed, they began digging for Employee #1, and were soon joined by fire and other emergency personnel. Employee #1's head was uncovered first, and the rescuers attempted to get him breathing while the rest of his body was dug free. Employee #1 was pronounced dead at the scene at 4:26 p.m. Apparent hazards identified at the site included an accumulation of water, lack of proper sloping of the excavation walls, inadequate protection of the excavation surface, and obstructed egress.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300362175 | Fatality | Asphyxia | Occupation not reported |
Translate