Accident Summary Nr: 170562870 - Employees subjected to accidental chlorine release

Accident Summary Nr: 170562870 -- Report ID: 0854910 -- Event Date: 12/21/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
12462343012/22/199328410Thatcher Co

Abstract: An employee was changing a short piece of copper tubing used to fill ton chlorine containers. He closed the valve on the cylinder, but failed to close the auxiliary bleed valve. The scrubber contained most of the gas, but it was overwhelmed and the gas filled the room. Employees #1 through #6 were transported to the hospital for observation.

Keywords: MAINTENANCE, ASPHYXIATED, WORK RULES, GAS, CHLORINE, AIR CONTAMINATION, VALVE, TOXIC FUMES, ACCIDENTAL DISCHARGE, INATTENTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 124623430 Hospitalized injury Poisoning(Systemic) Miscellaneous plant and system operators
2 124623430 Non Hospitalized injury Poisoning(Systemic) Miscellaneous plant and system operators
3 124623430 Non Hospitalized injury Poisoning(Systemic) Miscellaneous plant and system operators
4 124623430 Non Hospitalized injury Poisoning(Systemic) Miscellaneous plant and system operators
5 124623430 Non Hospitalized injury Poisoning(Systemic) Miscellaneous plant and system operators
6 124623430 Hospitalized injury Poisoning(Systemic) Miscellaneous plant and system operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.