Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170562607 - ELECTRIC SHOCK - GROUND FAULT IN ELECTRIC GRINDER

Accident Summary Nr: 170562607 -- Report ID: 0854910 -- Event Date: 09/28/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
12462027909/29/199315410Western General Constructoin

Abstract: An employee of a construction firm was working in the conveyor pit of a truck hopper. His supervisor had assigned him the task of cutting and installing a piece of rubber at the base of the conveyor. When he was finished, he was to clean up. The employee was reported missing by his father later that evening. The employee was found dead at about 2 AM the next morning by an employee of a minerals company. The pit had had problems of ground water seepage, and the dead employee was found lying on his right side in about 18 inches of water. He was wedged between a half-submerged, 6-inch-diameter pipe and a concrete wall. He was holding the power supply cord for an electric grinder in one hand, and the cord was plugged into an extension cord set. Burn marks were found on the dead employee's hand and chest. The blade for the ungrounded circuit conductor on the grinder's attachment plug and the corresponding slot on the cord connector on the cord set had been melted off. The employee had been electrocuted.

Keywords: ELECTRICAL, CORD SET, E GI VII, ELECTROCUTED, ATTACHMENT PLUG, GROUND FAULT, CORD CONNECTOR, EQUIPMENT GROUNDING, ELEC PORT TOOL--MISC

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 124620279 Fatality Electric Shock Construction trades, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close