Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170390678 - Employee killed in fall from steel I-beam

Accident Summary Nr: 170390678 -- Report ID: 0551800 -- Event Date: 12/15/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
12541727912/29/199717910Poe Steel Erection Inc

Abstract: At approximately 10:15 a.m. on December 15, 1998, Employee #1, an iron worker, and a coworker were positioning a 22 in. long crane rail on a 14 in. wide red iron I-beam. They were picking up the rail, one at each end, when it bowed, causing them to lose control and the rail to fall to the floor. Employee #1 then moved toward an extension ladder secured to a steel girt approximately 3 ft away. He missed the ladder and fell approximately 19 ft to the concrete floor. Employee #1 was transported to the hospital, where he died on December 23, 1998, of a herniated brain stem. No fall protection was used, and employees were not provided with safety training or an adequate safety program.

Keywords: STEEL BEAM, IRON WORKER, WORK RULES, CONSTRUCTION, MANUAL MAT HANDLING, FALL, FALL PROTECTION, WALKING ON BEAM, UNTRAINED, UNSTABLE POSITION
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building Maintenance or repair Under $50,000 3 20 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 125417279 Fatality Other Structural metal workers Distance of Fall: feet
Worker Height Above Ground/Floor: 20 feet
Cause: Steel Erection Of Open Web Steel Joists-Bolting-Up
Fatality Cause: Fall from/with ladder

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.