Accident Summary Nr: 170388037 - ELECTRIC SHOCK & BURN - OVERHEAD LINE FELL ON ROLLER COASTER

Accident Summary Nr: 170388037 -- Report ID: 0551800 -- Event Date: 07/03/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
12399821307/05/199479990Cumberland Valley Shows

Abstract: A large Ferris wheel was being set up at a carnival. The Ferris wheel contacted a 7200-volt overhead power line, severing it. The power line fell onto the tracks of a roller coaster ride. Three employees who were apparently in contact with the roller coaster received burns and electric shocks as a result of the contact. One suffered third-degree burns and had her right arm amputated at the shoulder. The second employee suffered third-degree burns on his right leg at the knee. The third employee received first- and second-degree burns. The employees were all hospitalized for their injuries.

Keywords: BURN, AMUSE PARK/CARNIVAL, AMPUTATED, OVERHEAD POWER LINE, ELECTRICAL, ELECTRIC SHOCK, AMUSEMENT RIDE, ARM, E GI IC, LEG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 123998213 Hospitalized injury Electric Shock Attendants, amusement and recreation facilities
2 123998213 Hospitalized injury Electric Shock Attendants, amusement and recreation facilities
3 123998213 Hospitalized injury Electric Shock Attendants, amusement and recreation facilities

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.