Accident Report Detail
Accident Summary Nr: 170382469 - Employee injured by spinning steel rod in lathe
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 125983619 | 09/13/1996 | 3949 | 0 | Paramount Fitness Corp. |
Abstract: Employee #1 was using a numerical automated lathe to mill 3 in. pins from 3/4 in. diameter stock on . He put a 71 3/4 in. long piece into the lathe. The excessive projection of the stock from the head, which was rotating at 1,500 rpm with chuck pressure at 400 psi, caused the stock to wobble and bend rapidly. Employee #1 tried to control the wobbling stock by hand instead of stopping the lathe. He lost his grip on the stock and the rotating stock struck him, fracturing a bone. The head stock was too large for the 3/4 in. stock being used, and the steel filler sleeve allowed too much stock to project from the head stock.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 125983619 | Non Hospitalized injury | Fracture | Lathe and turning machine operators |
Translate