Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170356752 - Employee enters contaminated water tank, has heart attack

Accident Summary Nr: 170356752 -- Report ID: 0950633 -- Event Date: 05/27/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
11994537606/09/199415420Falcon General Engineering Inc

Abstract: Employee #1 was instructed to enter a 1.5 million gal water tank to take water samples to determine what was contaminating the tank water. The water tank measured 40 ft high and 80 ft in diameter. The smell of the tank prior to entry was similar to creosote or diesel. Employee #1 entered the tank, which was 1/2 to 2/3 full of water and had an inside temperature of 100 degrees F with high humidity, without appropriate pre-entry monitoring. After taking water samples, Employee #1 had difficulty ascending the interior fixed ladder. He experienced severe breathing difficulties and later that afternoon went to the emergency room of Hemet Valley Hospital. The attending physician diagnosed Employee #1 as suffering a myocardial infarction due to the breathing of petroleum vapors. Analysis of water samples taken from the tank revealed diesel contamination.

Keywords: CONFINED SPACE, PPE, TOXIC WASTE, HEART ATTACK, WORK RULES, CONSTRUCTION, OVEREXPOSURE, WATER TANK, HIGH TEMPERATURE, RESPIRATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 119945376 Hospitalized injury Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close