Accident Report Detail

Accident Summary Nr: 170355796 - Employee's arm caught in rotating bowl of cement truck

Accident Summary Nr: 170355796 -- Report ID: 0950631 -- Event Date: 07/22/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
11988722207/29/199475380Industrial Repair

Abstract: On July 22, 1994, Employee #1, a contract employee working at a concrete ready-mix facility, was repairing the motor that controls the rotation of the bowl of a concrete ready-mix truck while the bowl was rotating. He had his left arm between the bowl and the motor when a projection on the bowl caught his arm. He suffered an open ulnar fracture that required extensive surgery. Employee #1 had failed to turn off the rotating bowl while attempting repairs.

Keywords: FRACTURE, ROTATING PARTS, REPAIR, WORK RULES, CAUGHT BY, LOCKOUT, TRUCK, ARM

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 119887222 Hospitalized injury Fracture Bus, truck and stationary engine mechanics

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.