Accident Summary Nr: 170341002 - Employee ill when exposed to hydrogen fluoride

Accident Summary Nr: 170341002 -- Report ID: 0317900 -- Event Date: 02/15/1996
Inspection NrDate OpenedSICNAICSEstablishment Name
12203055402/16/199634430Goodhart Sons, Inc.

Abstract: Employees were installing a new pump in building #73 of a chemical plant that extracts tantalum and niobium from raw ore. A chemical plant operator placed a dumpster containing waste product and residual hydrofluoric acid in the area where Employees #1, #2, and #3, contractors, were working. The plant operator was not aware that the employees were in the area. When Employees #1 through #3 smelled the acid, they knew it was hazardous from the training they had received and were cautious. The operators in the building told the employees to go to the dispensary and have someone call an ambulance. When the ambulance arrived, Employees #1, #2, and #3 were given calcium glutonate intravenously to prevent injury from the hydrogen fluoride. The employees were admitted to the hospital for overnight observation because they lived a significant distance away from the hospital. Employees #1, #2, and #3 did incur some lung burns. The site emergency response team responded to the area of the exposure and determined with a detector tube that the air contamination level was approximately 3.5 ppm.

Keywords: LUNG, HYDROGEN FLUORIDE, INHALATION, AIR CONTAMINATION, CHEMICAL BURN, OVEREXPOSURE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 122030554 Hospitalized injury Other Occupation not reported
2 122030554 Hospitalized injury Other Occupation not reported
3 122030554 Hospitalized injury Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.