Accident Summary Nr: 170250831 - Employee fractures fingertips in press

Accident Summary Nr: 170250831 -- Report ID: 1055360 -- Event Date: 07/20/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
11126597107/20/199434440Ecolite Manufacturing Co Inc

Abstract: While forming parts on a mechanical press, Employee #1 reached into the press with both hands to retrieve a part. The press cycled unexpectedly, fracturing the tips of the employee's index fingers. The press was protected by a two-hand trip. It is believed that a faulty brake shoe on the flywheel allowed the press to cycle. The press was dismantled and the brakes rebuilt.

Keywords: FRACTURE, BRAKE, FINGER, WORK RULES, STRUCK AGAINST, TWO-HAND CONTROL, MECH MALFUNCTION, PRESS

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111265971 Non Hospitalized injury Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.