Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170245906 - Seven employees burned, one killed, in refinery explosion

Accident Summary Nr: 170245906 -- Report ID: 1055310 -- Event Date: 01/19/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11145349401/19/199151720B P Oil

Abstract: At approximately 4:15 p.m. on January 19, 1991, Employees #1 through #7 were working at a refinery, pulling a blind out of a 24 in. transfer line between a crude oil heater and an atmospheric tower. The burners on the side of the crude heater opposite the transfer lines were on, but pinched back to the pilot setting. The atmospheric tower was left full of hydrocarbon product. Nitrogen was pumped into the transfer line through a bleeder on the tower side of the blind. All of this was done at the start of the project; pulling the blind was the last task. When the blind was opened, the nitrogen flowed out, followed by hydrocarbon vapors from the tower. The vapors were pulled through the heater and ignited by the pilot light. There was an explosion inside the heater that ignited the vapors outside, resulting in a second explosion. Employees #1 through #7 were hospitalized for burns; Employee #4 died that night as a result of his injuries. Three of the employees worked for the refinery; the remaining four worked for a subcontractor.

Keywords: BURN, VAPOR, FLAMMABLE VAPORS, NITROGEN, EXPLOSION, CHEMICAL VAPOR, REFINERY

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111453494 Fatality Burn/Scald(Heat) Occupation not reported
2 111453494 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 111453494 Hospitalized injury Burn/Scald(Heat) Occupation not reported
4 111453494 Hospitalized injury Burn/Scald(Heat) Occupation not reported
5 111453494 Hospitalized injury Burn/Scald(Heat) Occupation not reported
6 111453494 Hospitalized injury Burn/Scald(Heat) Occupation not reported
7 111453494 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close