Accident Summary Nr: 170245898 - Employee's Fingers Amputated in Drill

Accident Summary Nr: 170245898 -- Report ID: 1055310 -- Event Date: 12/03/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11144496401/11/199132730Builders Concrete Inc/Dba Bellingham Marine Ind

Abstract: Employee #1, age 17, was drilling holes into 20-ft-long by 3-in. by 10-in. boards. The 3.5-in.-diameter holes were countersunk 1 in. Employee #1 moved one board down the roller table to drill the last hole, turned his head, and pushed with his left hand. His rubber glove caught on the drill bit and was drawn into the drill. Three of his fingers were amputated. Employee #1 was wearing gloves because the boards were wet.

Keywords: CLOTHING, ROTATING PARTS, AMPUTATED, FINGER, GLOVE, CAUGHT BY, BORING MACHINE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111444964 Hospitalized injury Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.