Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170243661 - Three employees exposed to chlorine gas

Accident Summary Nr: 170243661 -- Report ID: 1055340 -- Event Date: 04/14/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
11527344304/22/199733410Goldendale Aluminum Company

Abstract: At approximately 9:30 a.m.. on April 14, 1997, Employee #2 began to put furnace #3 on flux. Adhering to established procedure, he opened the main upstream chlorine valve first, intending to open the downstream chlorine control valve to control the flow. With no outlet for the gas, which was flowing at 30 psi, the pressure dead-ended in the flowrator and sent the metal float in the flowrator shooting to the top of the Pyrex tube. The float broke through the glass tube, releasing chlorine gas into the face of Employee #2. Employee #1 was approximately 25 ft away, and helped Employee #2 to a safe place. Employee #1 then went to activate the nearest chlorine alarm. On the way, he donned an emergency respirator, but was unable to get it to function, and passed through the chlorine cloud twice again without respiratory protection. Employee #3, in the pit area near the furnace, also was unable to get a nearby respirator to function, and was exposed to chlorine gas. The primary causes of the accident were the employer's failure to implement in sufficient detail the requirements of PSM, failure to perform a hazard analysis of the furnace fluxing procedure, and failure to develop a safe written operation procedure. Factors contributing to employees' injuries included the poor location and inaccessibility of the manual-activation alarms and emergency respirators, and the fact that the respirators did not function properly.

Keywords: PPE, WORK RULES, INHALATION, EQUIPMENT FAILURE, GAS, CHLORINE, CHEMICAL VAPOR, ACCIDENTAL DISCHARGE, RESPIRATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 115273443 Hospitalized injury Other Occupation not reported
2 115273443 Non Hospitalized injury Other Occupation not reported
3 115273443 Hospitalized injury Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.