Accident Report Detail
Accident Summary Nr: 170235568 - Employee crushed and killed underneath van
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 111472940 | 07/31/1991 | 7532 | 0 | Chris Auto Rebuild Inc |
Abstract: At approximately 3:30 p.m. on July 31, 1991, Employee #1 crawled under a 14,000 lb GVW van to remove the driveline. He was preparing the vehicle to be towed. The van, which was on a slight incline, was in low gear and the emergency brake was set. The emergency brake on the van was not connected to the rear wheels but to the rear of the transmission. This meant that if the driveline was removed, the emergency brake would release. Not knowing this, the employee did not block the tires or hook his tow truck to the vehicle to keep it from rolling when he removed the driveline. As a result, the van rolled backward, crushing the employee between the floor of the van and the ground. He was killed.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 111472940 | Fatality | Asphyxia | Occupation not reported |