Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170218176 - Employee killed by elevator after failing to lock it out

Accident Summary Nr: 170218176 -- Report ID: 0552652 -- Event Date: 01/04/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
11488291301/05/199470110Sugarloaf Resort

Abstract: On January 4, 1994, Employee #1, of Sugarloaf Resort, was attempting to repair an elevator. He was not trained properly and did not lock out or block the equipment after defeating the safety interlock system. While he was bent over in the elevator shaft, the elevator came down and crushed him between the bottom of the elevator car and the floor of the door opening. Employee #1 died. The employer received a serious citation.

Keywords: REPAIR, WORK RULES, LOCKOUT, CRUSHED, ELEVATOR, UNTRAINED, ELEVATOR SHAFT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 114882913 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.