Accident Report Detail

Accident Summary Nr: 170210694 - Employee dies of asphyxia in oxygen deficient manhole

Accident Summary Nr: 170210694 -- Report ID: 0552651 -- Event Date: 09/17/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
11483493009/20/199316230Dans Excavating Inc

Abstract: On September 17, 1993, Employee #1, of Dan's Excavating Inc., a laborer on a sewer construction crew, entered a 26 ft deep manhole to check the line sight glass for water levels. After he had climbed to the bottom of the manhole, Employee #1 made a noise as if he were clearing his throat and then started climbing back out. When Employee #1 was 6 to 8 ft from the top he looked up, let go of the ladder, and fell backward to the bottom of the manhole. Employee #1 died of asphyxia. The atmosphere had not been tested before he entered the manhole. When it was later tested at the manhole level from which Employee #1 fell, an oxygen deficiency was found. Citations were issued for serious violations of R408.40121(1), R408.40121(2), and R408.41115(8).

Keywords: OXYGEN DEFICIENCY, ASPHYXIATED, CONFINED SPACE, WORK RULES, CONSTRUCTION, MANHOLE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 114834930 Fatality Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close