Accident Summary Nr: 170210207 - Employee dies after forklift and platform overturn

Accident Summary Nr: 170210207 -- Report ID: 0552651 -- Event Date: 01/08/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
11465177101/08/199217410Concepts In Carpentry Inc

Abstract: On January 8, 1992, four employees of Concepts in Carpentry began work by loading a tab-built platform, which was being used with a Pettibone C-8000 articulating forklift, with material and tools needed for their work. The foreman drove the forklift to the east side of the church. Extension cords were hooked up to the power source and then extended to the platform. Employee #1 and two coworkers got into the work platform, which was 12 feet away from the building. The foreman raised them approximately 35 to 40 ft high to the church's peak. He set the micro brake, but the parking brake could not be set because it had been disconnected 10 months earlier. The foreman left the forklift and entered the building. A few minutes later Employee #1, on the platform, yelled that the forklift was moving away from the building. The two coworkers jumped onto the roof of the church, but Employee #1 stayed on the platform. When the forklift hit some bad ground it started rocking north to south. The left rear wheel dropped into a hole and the forklift tipped to the south onto its left side. Employee #1 was thrown to the frozen ground. CPR was administered to him until the paramedics arrived. He was transported to McPherson Hospital, where he was pronounced dead on arrival.

Keywords: CHOCK, BRAKE, UNEVEN GROUND, CPR, INADEQUATE MAINT, CONSTRUCTION, INDUSTRIAL TRUCK, ELEVATED WORK PLAT, OVERTURN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 114651771 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close