Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170210173 - Employee dies after falling 15 ft through floor opening

Accident Summary Nr: 170210173 -- Report ID: 0552651 -- Event Date: 11/12/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11490407111/14/199117990Labor Resources Corp

Abstract: On November 12, 1991, Employee #1 and a coworker were power washing and removing paint from the interior concrete surface of a water filtration plant. The cover had been removed from a 3 ft by 6 ft floor opening to facilitate paint removal adjacent to the opening. Employee #1 fell 15 ft 7 in. through the opening onto metal pipe that was stored in the basement. He sustained massive head and back injuries from which he died.

Keywords: HEAD, COVER, CLEANING, STRUCK AGAINST, CONSTRUCTION, BACK, FALL, FLOOR OPENING, METAL PIPE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 114904071 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.