Accident Summary Nr: 170203830 - Employee injured when struck by falling metal weight

Accident Summary Nr: 170203830 -- Report ID: 0950624 -- Event Date: 07/02/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11192131807/03/199113890Well-Tech Inc.

Abstract: On July 2, 1991, Employee #1 was working as a floorman on an oil rig when the rig operator allowed the traveling block to overtravel and strike the crown block. The impact caused a metal weight to be sheared off. Employee #1 sustained multiple fractures when he was struck on the arm, face, and side by the falling weight. The rig operator later stated that he been distracted from watching the weight indicator while pulling a bridge plug out of the well hole. He failed to notice the emergence of the pipe coupling, which was his normal indicator to stop the upward movement of the traveling block.

Keywords: FRACTURE, TRAVELLING BLOCK, STRUCK AGAINST, OIL WELL SERVICING, STRUCK BY, FALLING OBJECT, SHEARED, OIL RIG, INATTENTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111921318 Hospitalized injury Fracture Drillers, oil well

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close