Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170203715 - One killed, three hurt when crane counterweights fall

Accident Summary Nr: 170203715 -- Report ID: 0950626 -- Event Date: 09/07/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11194214009/02/199073530Neil F. Lampson Inc.- Area 1125 -Ic
Inspection NrDate OpenedSICNAICSEstablishment Name
11194215709/07/199087310Hercules Aerospace Company
Inspection NrDate OpenedSICNAICSEstablishment Name
11194213209/07/199087310Wyle Laboratories

Abstract: At approximately 10:56 a.m. on September 7, 1990, Employees #1 through #4 were helping to hoist and move a Titan AFT rocket motor segment from a test stand. A Lampson Crane, model LTL900, was seated on sheets of plywood that were placed on a 7 1/4 in. to 8 in. deep surface of pea-like gravel and road base aggregate that had been spread over the uneven fractured concrete surface. During a counterrotation of the crane's front crawler, the left track of the crawler sank into the pea-like gravel, resulting in the crane boom going too far out of horizontal level. The rocket motor then swung out beyond the crane's safe design limit, causing the main boom center pin to break loose. The main boom of the crane fell to the left, and the AFT rigging strut knocked off the left counterweights, which fell on Employee #1. He was crushed and killed. Employees #2 through #4 also sustained injuries; only Employee #2 was hospitalized.

Keywords: UNEVEN GROUND, WORK RULES, CRANE COUNTERWEIGHT, CRANE BOOM, CRAWLER CRANE, CRUSHED, STRUCK BY, UNSTABLE SOIL, FALLING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111942140 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported
2 111942157 Occupation Not Listed
3 111942132 Fatality Other Occupation not reported
4 111942132 Non Hospitalized injury Puncture Occupation not reported
5 111942132 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close