Accident Summary Nr: 170203236 - Employee's hand burned by acidic solution

Accident Summary Nr: 170203236 -- Report ID: 0950626 -- Event Date: 08/04/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11194186008/28/199051470Bernard And Sons

Abstract: Employee #1, of Bernard and Sons, Inc., in Bakersfield, CA, was cleaning the bumper and other parts of a vehicle with Trailmobile cleaner and brightener, which contains hydrofluoric and sulfuric acids. He was using a 1:1 dilution instead of the 1:30 dilution recommended by the manufacturer. He was applying the cleaner with a brush, but was not wearing any gloves or other protective clothing. Some of the cleaner got on one of Employee #1's hands, causing a chemical burn. Employee #1 had not been trained in the hazards associated with using Trailmobile cleaner and brightener.

Keywords: PPE, HYDROFLUORIC ACID, WORK RULES, CLEANING, CHEMICAL BURN, CLEANING FLUID, SKIN, SULFURIC ACID, UNTRAINED, HAND

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111941860 Hospitalized injury Burn(Chemical) Truck drivers, heavy

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close