Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170202170 - Employee feels ill after dust exposure

Accident Summary Nr: 170202170 -- Report ID: 0950625 -- Event Date: 08/14/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11192669708/28/199013820K.M. Scrivner

Abstract: On August 14, 1990, Employee #1, working for an oilfield service contractor, was sent with two coworkers and a supervisor to the Calaveras Avenue Unocal gas refinery to service a hydrogen sulfide strip. The process called for the removal of a catalyst from three small, 5 ft tall by 4 ft in diameter, vessels. The Unocal crew removed the vessel lids and tested the atmosphere for hydrogen sulfide and oxygen. Less than 1 percent hydrogen sulfide was detected, and the oxygen level was 21 percent. At this point, Unocal suggested to Employee #1 and coworkers that they needed only dust masks for respiratory protection, and not the Scott Air Paks that they had brought to the site. The workers had not been fit tested nor trained in the use of dust masks because no monitoring was conducted for vanadium pentoxide dust. They completed the work by leaning over the edges of the vessels and removing the pelletized catalyst with coffee cans. It took two days, working 4 to 5 hours per day, to recharge the catalyst. On the morning of August 16, Employee #1 reported that he felt ill. He was admitted to Avenal Hospital, reporting flu-like symptoms and a headache. He was treated for headache and high blood pressure; the treating physician's diagnosis was that the symptoms were caused by exposure to vanadium pentoxide. Employee #1 had worn a dust mask for 30 minutes on August 14, then used his Scott Air Pak for the rest of the August 14 and all day on August 15. The two coworkers engaged in exactly the same task and wore the dust masks the entire time on August 14 and 15. Neither of them reported feeling ill. A supervisor later stated that he believed Employee #1's illness was due to alcohol because Employee #1 had told him that he had drunk heavily on the night of August 15.

Keywords: RESPIRATORY, ALCOHOL, PPE, HEADACHE, WORK RULES, INHALATION, OIL WELL SERVICING, POISONING, DUST INHALATION, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111926697 Hospitalized injury Poisoning(Systemic) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close