Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170200679 - Employee injured in fall through storage rack deck

Accident Summary Nr: 170200679 -- Report ID: 0950621 -- Event Date: 02/12/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11185326302/15/199124340Continental Store Fixtures

Abstract: At approximately 7:30 a.m. on February 12, 1991, Employee #1 was dismantling metal pallet storage racks. He was working from a pallet elevated on the forks of a forklift to the third tier of the metal rack, approximately 8 ft above the floor. He stepped from the pallet platform onto the storage rack deck. The 3/4 in. thick particleboard broke under his weight, and he fell to the floor. Employee #1 suffered scratches, bruises, and a back injury.

Keywords: DISMANTLING, COLLAPSE, DECKING PANEL, OVERLOADED, BACK, FALL, FALL PROTECTION, STORAGE RACK, ELEVATED WORK PLAT, CONTUSION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111853263 Hospitalized injury Strain/Sprain Miscellaneous precision woodworkers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.