Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170199608 - Employee's forearm crushed during rigging operation

Accident Summary Nr: 170199608 -- Report ID: 0950625 -- Event Date: 05/11/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
11976369607/13/199513810Gary Drilling

Abstract: At approximately 10:15 a.m. on May 11, 1995, Employee #1 was involved in rigging up operations at rig #9 at the Midway Sunset oil field in Maricopa, CA. His left arm became caught between the snubbing post and the derrick leg. He was taken to a doctor and later transported to Encino Hospital for treatment of crushing injuries to his forearm.

Keywords: DERRICK, RIGGING, FOREARM, OIL WELL DRILLING, CAUGHT BETWEEN, CRUSHED, OIL RIG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 119763696 Hospitalized injury Fracture Helpers, extractive occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.