Accident Summary Nr: 170199285 - Employee suffers chemical burns from anhydrous ammonia

Accident Summary Nr: 170199285 -- Report ID: 0950626 -- Event Date: 06/06/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11194569706/07/199120370Grimway Farms Dba Grimway Frozen Foods

Abstract: At approximately 2:00 p.m. on June 6, 1991, Employee #1 was scraping paint from the side of a building and from some piping outside the building wall that carried anhydrous ammonia (NH3). He was working from a manlift that only traveled up and down. As the manlift descended, it struck the end of a horizontal 7 in. long by 1/2 in. diameter copper pipe. The pipe broke at the threaded connection, which allowed anhydrous ammonia at 130 psi to escape from the refrigeration system. Employee #1 sustained chemical burns on his arms and the plant was evacuated. Eleven workers were checked out at the hospital for anhydrous ammonia inhalation and were released by 4:00 p.m. the same day. Maintenance employees wearing SCBA closed two valves to shut off the escaping ammonia.

Keywords: CAUSTIC, STRUCK AGAINST, ANHYDROUS AMMONIA, CHEMICAL BURN, GAS LEAK, SKIN, ARM, CHEMICAL VAPOR, ACCIDENTAL DISCHARGE, AERIAL LIFT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111945697 Non Hospitalized injury Burn(Chemical) Painters, construction and maintenance

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close