Accident Summary Nr: 170197222 - Employee sustains multiple burns from residue release

Accident Summary Nr: 170197222 -- Report ID: 0950622 -- Event Date: 08/22/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
12018585508/23/199429110Tosco Refining Company

Abstract: At approximately 11:13 p.m., Employee #1, of Tosco Avon Refinery, was removing a pump, #PU8089, from service for maintenance. He closed the discharge valve and shut down the power to the motor. Employee #1 was closing the suction valve when the Pathway Bellows expansion joint, ID #PN12-TUFF-150-32-LC-M4-X, ruptured and discharged residue at a temperature of approximately 700 degrees Fahrenheit. Employee #1 was hit by the material, sustaining 2nd- and 3rd-degree burns to his arms, back, and buttocks. A coworker helped him out of the area. The residue caused a fire and the refinery's HERO team responded. At 12:25 a.m. the all clear was sounded. The expansion joint was exposed to the pump discharge pressure because the warm-up line was open. The thinned spool between the bellows was unable to contain the pressure and ruptured.

Keywords: BURN, FIRE, EQUIPMENT FAILURE, RUPTURE, BACK, HIGH PRESSURE, ARM, ACCIDENTAL DISCHARGE, REFINERY, HIGH TEMPERATURE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 120185855 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close