Accident Summary Nr: 170195895 - Employee killed when struck by pool filter housing

Accident Summary Nr: 170195895 -- Report ID: 0950623 -- Event Date: 07/22/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11190102107/23/199070110Anderson Valley Inn Motel

Abstract: Employee #1 had completed service on a large stainless steel swimming pool filter. When the filter was turned on, he noted that the water pressure was 35 psi at the top of the filter. Apparently, the backwash valve was blocking both the backwash escape line and the filter return line to the pool. The pool's electric water pump was pushing water into the filter with no method of discharge. The pressure continued to build to the point of metal fatigue, until the two-part filter housing flew apart. The upper half of the housing struck Employee #1 in the head. He was killed. The backwash valve blockage was not detectable when the system was in operation.

Keywords: HEAD, MAINTENANCE, CLOGGED, POOL, HIGH PRESSURE, VALVE, STRUCK BY, FLYING OBJECT, MECH MALFUNCTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111901021 Fatality Concussion Janitors and cleaners

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close