Accident Summary Nr: 170195432 - Employee in tunnel struck by falling rock

Accident Summary Nr: 170195432 -- Report ID: 0950651 -- Event Date: 09/14/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11195827809/19/199016220Iron Mountain Trust

Abstract: At about 8:30 on September 14, 1990, Employee #1, along with two coworkers, was resetting a steel ground support set in a 9 ft by 7 ft diversion tunnel. The set had been installed 3 1/2 in. too low. The crew had previously installed and blocked in a steel set in the open face. Then, according to plan, they loosened the misaligned set, barred down loose rocks, and lifted the set into position using the LDH Wagoner machine. They were then to insert 3 1/2 in. blocks under the set. They had set one block under the set and, while the crew's attention was on the job of placing the second block under the set, some rocks were either dislodged or came loose and struck Employee #1 on the back. He was dragged away from the danger area and given first aid for a gouge wound on his back. He was then removed to Mercy Hospital, where he was confined for 24 hours of observation. He reported back to work on September 18, 1990, for light duty restriction. Attention to the tunnel roof and rib could have provided Employee #1 with an additional margin of safety.

Keywords: TUNNEL, ROCK, WORK RULES, CONSTRUCTION, BACK, STRUCK BY, FALLING OBJECT, INATTENTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111958278 Non Hospitalized injury Cut/Laceration Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close