Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170192496 - Employee buried and killed when excavation caves in

Accident Summary Nr: 170192496 -- Report ID: 0950633 -- Event Date: 01/06/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
11205712001/07/199216290Yuma Sprinkler & Pipe Co

Abstract: At approximately 11:45 a.m. on January 6, 1992, Employee #1, of Yuma Sprinkler and Pipe Company, entered a 2 ft wide by approximately 12 ft deep excavation. The west side of the trench caved in, burying him. Employee #1 was killed. The excavation was not sloped, shored, or benched.

Keywords: EXCAVATION, WORK RULES, CONSTRUCTION, TRENCH, SHORING, SLOPING, BURIED, CAVE-IN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112057120 Fatality Asphyxia Sales occupations, other business services

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.