Accident Summary Nr: 170190136 - Employee killed when crushed by tipping dump truck

Accident Summary Nr: 170190136 -- Report ID: 0950632 -- Event Date: 11/03/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
11201542511/03/199242120Debris Box

Abstract: Employee #1, the driver of a truck, was preparing to dump a load of construction debris when the dump trailer of a truck owned by another employer tipped over and fatally crushed Employee #1 while he was inside his cab. A combination of factors contributed to the accident: the ground, which was not firm enough to keep the truck stable; gusty winds; improper load distribution in the second truck; and the unsafe practice of moving a dump truck forward while dumping the load.

Keywords: HIGH WIND, WORK RULES, CRUSHED, DUMP TRUCK, UNSTABLE SOIL, OVERTURN, TRUCK DRIVER, UNSTABLE LOAD

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112015425 Fatality Other Truck drivers, heavy

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.