Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170187199 - Employee's fingers amputated when circular saw kicks back

Accident Summary Nr: 170187199 -- Report ID: 0950635 -- Event Date: 07/30/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11207879508/02/199017510R.L.O. Corporation Dba Olson Construction Co.

Abstract: At approximately 3:25 p.m. on July 30, 1990, Employee #1, a laborer for KLO Corporation, dba Olson Construction Company, was cutting 1 in. square notches out of the corners of a 6 in. piece of 2 by 6 wood. To do this, he wedged up the guard on the portable, power-driven, circular hand saw. The saw kicked back, amputating three fingers on his left hand. Employee #1 was transported to Terrence Memorial Hospital for treatment.

Keywords: KICK BACK, PORTABLE POWER TOOL, AMPUTATED, FINGER, GUARD, WORK RULES, CONSTRUCTION, CIRCULAR SAW, ELECTRIC SAW, SAW

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112078795 Hospitalized injury Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.