Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170185409 - Employee injured when sleeve caught in mixer

Accident Summary Nr: 170185409 -- Report ID: 0950643 -- Event Date: 03/25/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11187959903/28/199151690Hexcel Corp.

Abstract: Employee #1, of Hexcel Corporation, was mixing epoxy chemicals in a vat. The epoxy started to creep up the walls of the vat and he took a spatula and started to push it back into the vat without shutting off the mixer. His sleeve became entangled in the rotating shaft, which pulled his arm around it. He suffered a broken arm and collarbone before the machine was shut off.

Keywords: CLOTHING, FRACTURE, ROTATING SHAFT, WORK RULES, COLLARBONE, MIXER, CAUGHT BY, LOCKOUT, ARM, ENTANGLED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111879599 Hospitalized injury Fracture Mixing and blending machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.