Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170182208 - EMPLOYEE INJURED IN UNSTABLE CHEMICAL EXPLOSION

Accident Summary Nr: 170182208 -- Report ID: 0950644 -- Event Date: 07/11/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11220291607/16/199087310Fluorochem, Inc.

Abstract: THE COMPANY WAS PERFORMING RESEARCH AND DEVELOPMENT OF A HIGHLY UNSTABLE SUBSTANCE CALLED CUBONE, ATTEMPTING TO EXTRACT THE RESULTING HEXANE FROM THIS SUBSTANCE. THERE HAD BEEN A BOIL-OVER THE DAY BEFORE WHILE EMPLOYEE #1 WAS WORKING WITH IT, WHICH MADE IT EVEN MORE UNSTABLE. ON JULY 11, 1990, EMPLOYEE #1 WAS INSTRUCTED TO SALVAGE THE SUBSTANCE AND REWORK IT. EMPLOYEE #1 OBJECTED, BUT WAS INSTRUCTED TO DO SO ANYWAY. WHEN EMPLOYEE #1 REACHED FOR THE FLASK, IT EXPLODED. HE SUSTAINED THE LOSS OF TWO FINGERS AND OTHER SERIOUS INJURIES.

Keywords: AMPUTATED, FINGER, WORK RULES, EXPLOSION, CHEMICAL, HEXANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112202916 Hospitalized injury Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.