Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170180699 - Employee hospitalized after exposure to chlorine

Accident Summary Nr: 170180699 -- Report ID: 0950642 -- Event Date: 09/29/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11215483610/22/199149410California Water Service Company

Abstract: Employee #1 was replacing a chlorine compressed gas cylinder for chlorinating water for a utility services company. The employee had to remove a chlorinator from the old chlorine cylinder and attach the chlorinator to a new cylinder. The chlorinator has a feed tube and a vent tube. The vent tube normally leads up through the roof of the shack and vents to the outside. Employee #1 removed the chlorinator, then inadvertently pulled down the vent tube from the roof. The vent tube tail end was lying on the floor just outside the entrance to the shack. When the employee energized the cylinder, he noticed the vent tube on the floor. He reached to pick it up, causing an increase in pressure within the tube and forcing the chlorine out. Employee #1 inhaled the vapors and became ill. He was hospitalized.

Keywords: MAINTENANCE, VAPOR, CYLINDER, VENTING, INHALATION, CHLORINE, TOXIC FUMES, OVEREXPOSURE, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112154836 Hospitalized injury Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.