Accident Summary Nr: 170180590 - Employee's finger amputated in sausage extruder

Accident Summary Nr: 170180590 -- Report ID: 0950642 -- Event Date: 06/10/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11215346505/12/199120110Hoffman Brothers Packing Co Inc

Abstract: Employee #1, of Hoffman Brothers Packing, Inc., was operating a sausage extruder, a TRI-Power Extrusion Master molding machine, model MPD. Employee #1 opened the side safety guard cover to clear a paper jam. He put his left hand in, the sliding table cycled, and the machine sheared off his middle finger at the first joint. Although the side safety guard cover was equipped with a microswitch interlock, a manufacturer's label printed on the machine warned that, in addition to the interlock, the operating lever had to be turned off and the service cord disconnected before opening the machine. Employees, however, were accustomed to opening the machine to clear jams, and relied solely on the interlock to stop the machine. Operators and maintenance staff cleared jams this way daily.

Keywords: MEAT STUFFING MACH, AMPUTATED, FINGER, GUARD, MOLDING MACHINE, PACKING HOUSE, WORK RULES, INTERLOCK, JAMMED, LOCKOUT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112153465 Hospitalized injury Amputation Extruding and forming machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close