Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170180582 - Employee's arm fractured in press rollers

Accident Summary Nr: 170180582 -- Report ID: 0950642 -- Event Date: 07/11/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11215113907/17/199125220Alba Industries

Abstract: Between 3:00 and 3:30 p.m. on July 11, 1991, Employee #1, a laminating press operator for Alba Industries, was routinely cleaning the glue rollers of a laminating press. Following the daily procedure, Employee #1 washed down the rollers with a hose so the glue wouldn't harden. He held the hose in one hand, while scraping the glue off the rollers with a 10 in. to 12 in. long wire brush held with the other hand. The press was left on so the rollers would turn during cleaning. On this day, the feed opening between the roller was 1 in. to 1 1/8 in. Employee #1 was wearing a glove on the hand with which he was holding the wire brush. While he was cleaning the roller, his glove became caught between the rollers and his hand/arm was pulled into the machine. Employee #1 said he tried to stop the machine by tripping an emergency wire that was within reach of his other hand, but the switch did not work. Employee #1 suffered a fractured arm and was hospitalized for one week. There was no effective lockout or other blocking method used during this cleaning operation. In addition, there was not an effective stop device within Employee #1's reach.

Keywords: FRACTURE, GLOVE, WORK RULES, CLEANING, EMERGENCY STOP, LOCKOUT, ROLLER--MACH/PART, CAUGHT BETWEEN, ARM, MECH MALFUNCTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112151139 Hospitalized injury Fracture Miscellaneous machine operators, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.