Accident Summary Nr: 170179600 - EMPLOYEE INJURED BY GRINDER'S EXPOSED ROTATING CUTTERS

Accident Summary Nr: 170179600 -- Report ID: 0950645 -- Event Date: 12/17/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11202645512/17/199107830Santa Barbara Tree Service

Abstract: An employee of a tree service company was operating a rented Promark stump grinder (Model No. 94007). Warning labels (in English) at the grinder's controls and rotating cutters admonished the operator not to get near the cutters. Rental company employees indicated that they tell all grinder renters not to leave the controls because there is no clutch. However, the employer had not trained the employee in the proper operation of the grinder. The grinder was designed so that the weight of the 6.8- to 13.5-kilogram cutting head will cause the motor to stall if the operator releases the handle. The employee left the controls to walk to the cutting end to pick up a shovel, leaving the rotating cutters exposed and 600 to 900 millimeters off the ground. Unfortunately, the grinder did not stall as it was designed to do. The employee turned toward the grinder, and his left hand and forearm contacted the rotating blades, which cut tendons, skin, bones, and tissue. He was hospitalized for his injuries. The employee probably lost the use of two or three fingers on his left hand and was left with a deformed left arm.

Keywords: GRINDER, TREE STUMPING, INADEQUATE MAINT, ROTATING KNIFE, LACERATION, STRUCK BY, ARM, UNTRAINED, HAND

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112026455 Hospitalized injury Cut/Laceration Timber cutting and logging occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close