Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170177927 - Fifteen employees exposed to ethylene oxide

Accident Summary Nr: 170177927 -- Report ID: 0950643 -- Event Date: 11/15/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11216904012/13/199063240Holy Cross Medical Center

Abstract: On November 15, 1991, the Holy Cross Medical Center contracted to have the area surrounding the central supply ethylene oxide sterilizer monitored for emissions of ethylene oxide (EtO). An employee operated the sterilizer during the tests. Employees #1 through #11 and two coworkers were exposed to ethylene oxide levels in excess of the permissible exposure limit (PEL). Another coworker exceeded the short term exposure limit (STEL) while changing the EtO cylinder. On November 30, 1991, the employer monitored again with similar results. Employees #1 through #4, #7, #9 through #13, and three coworkers were exposed to levels over the permissible limits. No respiratory protection was worn by any of the employees. The following factors contributed to the EtO levels in the area: 1) the equipment room did not maintain negative pressure; 2) there was no local exhaust over the sterilizer; 3) there was no capture box at the sterilizer drain; 4) ventilation in the equipment room was insufficient; and 5) fugitive emissions were recirculated into the work area.

Keywords: VAPOR, VENTILATION, PPE, ETHYLENE OXIDE, WORK RULES, INHALATION, CHEMICAL VAPOR, OVEREXPOSURE, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112169040 Non Hospitalized injury Cancer Mechanical engineering technicians
2 112169040 Non Hospitalized injury Cancer Health technologists and technicians, n.e.c.
3 112169040 Non Hospitalized injury Cancer Health technologists and technicians, n.e.c.
4 112169040 Non Hospitalized injury Cancer Health technologists and technicians, n.e.c.
5 112169040 Non Hospitalized injury Cancer Health technologists and technicians, n.e.c.
6 112169040 Non Hospitalized injury Cancer Health technologists and technicians, n.e.c.
7 112169040 Non Hospitalized injury Cancer Health technologists and technicians, n.e.c.
8 112169040 Non Hospitalized injury Cancer Health technologists and technicians, n.e.c.
9 112169040 Non Hospitalized injury Cancer Health technologists and technicians, n.e.c.
10 112169040 Non Hospitalized injury Cancer Health technologists and technicians, n.e.c.
11 112169040 Non Hospitalized injury Cancer Health technologists and technicians, n.e.c.
12 112169040 Non Hospitalized injury Cancer Health technologists and technicians, n.e.c.
13 112169040 Non Hospitalized injury Cancer Health technologists and technicians, n.e.c.
14 112169040 Non Hospitalized injury Cancer Health technologists and technicians, n.e.c.
15 112169040 Non Hospitalized injury Cancer Health technologists and technicians, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.