Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170177893 - EMPLOYEE FELL FROM HOOK LADDER

Accident Summary Nr: 170177893 -- Report ID: 0950643 -- Event Date: 12/14/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11222671712/19/199048130Gte California Inc.

Abstract: A telephone worker was working from a hook ladder attached to a telephone cable strung between two utility poles. The cable was not quite horizontal, and the dirt on which the ladder was resting did not adequately support it. The employee fell from the ladder 2 to 3 meters to the ground (sandy dirt). He fractured the talus bone in his right ankle and was hospitalized for his injury.

Keywords: FRACTURE, TELECOM WORK, LADDER, UNSTABLE SURFACE, FALL, FALL PROTECTION, ANKLE, COMMUNICATION WORKER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112226717 Hospitalized injury Fracture Telephone line installers and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.