Accident Summary Nr: 170174270 - Employee struck by crane block

Accident Summary Nr: 170174270 -- Report ID: 0950614 -- Event Date: 07/13/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11182129408/14/199016110Glenwood Construction

Abstract: Employee #1 was standing under a crane when a wire rope parted and he was struck by the crane block. No other load was present. The mobile hydraulic boom crane did not have a current, annual certificate; maintenance records were not kept, and a daily pre-use safety inspection was not conducted by the employee. Evidence shows that the crane was overloaded and/or double blocked, indicating a lack of adequate operator training and/or supervising.

Keywords: WIRE ROPE, INADEQUATE MAINT, WORK RULES, BROKEN CABLE, EQUIPMENT FAILURE, INEXPERIENCE, STRUCK BY, CRANE BLOCK, FALLING OBJECT, HYDRAULIC CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111821294 Non Hospitalized injury Fracture Construction trades, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.