Accident Summary Nr: 170169213 - Three employees burned by chemical acid/proponal mixture

Accident Summary Nr: 170169213 -- Report ID: 0950612 -- Event Date: 04/08/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11176193804/09/199187310Lite-On Inc.

Abstract: Employee #1 was asked to perform a chemical etching procedure using propanol and concentrated hydrofluoric and nitric acids. The acids and the propanol were accidentally mixed, resulting in an exothermic reaction. Employee #1 suffered chemical burns on her the face, neck, and arms. Employee #3 suffered chemical burns on his arms while helping Employee #1 into the emergency shower and eye- and face wash facility. Approximately 2 hours later, Employee #2 poured the same waste acid/propanol mixture into a 5-gallon waste container, again producing an exothermic reaction. He suffered chemical burns on his face, neck, and arm.

Keywords: SHOULDER, CAUSTIC, HYDROFLUORIC ACID, WORK RULES, CHEMICAL REACTION, CHEMICAL BURN, NITRIC ACID, ARM, FACE, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111761938 Hospitalized injury Burn(Chemical) Engineering technicians, n.e.c.
2 111761938 Hospitalized injury Burn(Chemical) Chemical engineers
3 111761938 Hospitalized injury Burn(Chemical) Engineering technicians, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.