Accident Summary Nr: 170168470 - Employee injured in fall to ground with tower section

Accident Summary Nr: 170168470 -- Report ID: 0950623 -- Event Date: 07/16/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11196024107/18/199117910Bart Associates

Abstract: At approximately 1:00 p.m. on July 16, 1991, a 25 ft tall base section of a transmission tower was being dismantled at fly yard #2. Leg #4 had been removed; a crane was attached to leg #3 and a boom truck was attached to leg #2. Four employees were on the structure. Four rope guys were also securing the structure. The knee brace bolts between legs #1 and # 2 were inadvertently removed from the top level. The foreman told Employee #1 that the knee brace bolts between legs #2 and #3 were to be taken off. Employee #1 went to remove the bolts, leaving legs #1 and # 2 unbolted. As the knee braces were unbolted at legs #2 and #3, leg #1 began to rock and sway. It eventually fell to the ground toward leg #2. Employee #1, who was standing 18 ft above the ground on leg #1, fell with the leg and hit the ground. He was taken to Chico's Enloe Hospital for treatment of a fractured hip, shoulder blade, and ruptured spleen.

Keywords: FRACTURE, SHOULDER, SPLEEN, WORK RULES, CONSTRUCTION, RUPTURE, FALL, FALLING OBJECT, HIP, UNSTABLE POSITION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111960241 Hospitalized injury Fracture Structural metal workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close