Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170166094 - Employee's Thumb Amputated in Bench Press

Accident Summary Nr: 170166094 -- Report ID: 0950631 -- Event Date: 11/15/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11197440811/26/199024520Advanced Equipment Corporation

Abstract: At approximately 11:00 a.m. on November 15, 1990, Employee #1, of Advanced Equipment Corporation, was using a bench-mounted drill press to drill holes in a strip of metal. The gloves he was wearing caught in the rotating drill bit, resulting in the amputation of his thumb. Paramedics transported him to UC-Irvine Medical Center, where he was hospitalized for treatment. The supervisor stated that he had instructed employees not to wear gloves, rings, or any loose clothing when operating the machine because of the danger of being caught by moving parts. Before the accident, Employee #1 said that he was wearing gloves because he did not want to be cut by the strip of metal he was drilling.

Keywords: CLOTHING, ROTATING PARTS, AMPUTATED, GLOVE, WORK RULES, CAUGHT BY, THUMB, DRILL PRESS, PRESS OPERATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111974408 Hospitalized injury Amputation Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.