Accident Summary Nr: 170164016 - Employee injured when struck by falling conveyor gate

Accident Summary Nr: 170164016 -- Report ID: 0950631 -- Event Date: 06/22/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11197152908/03/199035710Advanced Logic Research

Abstract: At approximately 11:14 p.m. on June 22, 1990, Employee #1 was passing through the raised lift gate of a roller conveyor to inspect the computers on the conveyor. Employee #1 brushed against the gate and it fell, striking him on the head. He suffered a concussion and experienced post-cerebral concussion syndrome, with headache, amnesia, and cognitive impairment. The roller conveyor gate had a Powerise damper on both sides to ease lifting and holding it up. The damper was not operating properly and did not hold the gate up during the engineer's inspection on August 3, 1990. If the damper was not working, the gate would fall without some restraint. There was no latch, nor any other positive means to secure it when raised.

Keywords: HEAD, UNSECURED, HEADACHE, WORK RULES, ROLLER CONVEYOR, STRUCK BY, CONCUSSION, MECH MALFUNCTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111971529 Hospitalized injury Concussion Inspectors, testers and graders

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close