Accident Summary Nr: 170161582 - Employee injured when struck by abrasive wheel fragments

Accident Summary Nr: 170161582 -- Report ID: 0950632 -- Event Date: 04/25/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11201304004/30/199137280Rohr Industries Inc

Abstract: Employee #1 put a 6 in. abrasive wheel, manufactured by Matz Rubber Company, Inc., factory #608, A-80-E4-RR, rated at 3,600 rpm, on a Dotco portable pneumatic motor rated at 18,000 rpm. He was attempting to use the abrasive wheel for deburring a part when the wheel exploded. A fragment of the wheel struck him on the forehead and lodged in his skull. The fragment was surgically removed and he spent about a week in the hospital. There were no guards, flanges, or blotters on the mechanism.

Keywords: WORK RULES, FOREHEAD, SKULL, STRUCK BY, FLYING OBJECT, ABRASIVE WHEEL, GRINDING MACHINE, UNGUARDED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112013040 Hospitalized injury Cut/Laceration Hand cutting and trimming occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.