Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170156400 - Apprentice carpenter killed by collapsing falsework

Accident Summary Nr: 170156400 -- Report ID: 0950642 -- Event Date: 06/12/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
11215946206/12/199216220Mcm Construction Inc

Abstract: Employee #1, an apprentice carpenter, was removing falsework from underneath a freeway connector under construction. The falsework consisted of wooden forms resting on loose steel beams which were resting on vertical steel structures called bents. During this operation, while the bents are being lowered so that the beams can be removed, the wire rope guy lines that act as braces should be kept tight. On this day, the carpenters removed all the wire rope guys on one side of the beam and loosened all the guys on the other side of the beam. The whole structure collapsed domino style, and a 36 ft beam crushed and killed Employee #1. A qualified supervisor was not at the job site.

Keywords: BEAM, DISMANTLING, WIRE ROPE, COLLAPSE, CARPENTER, WORK RULES, CONSTRUCTION, CRUSHED, GUY, BRACING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112159462 Fatality Other Carpenter apprentices

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.