Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170153068 - Employee injured when struck on head by liquid cement

Accident Summary Nr: 170153068 -- Report ID: 0950641 -- Event Date: 11/30/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11211236212/11/199017410Pearman & Sons Inc.

Abstract: At approximately 1:00 p.m. on November 30, 1990, Employee #1, of Pearman and Sons, Inc., Gardena, CA, was operating a pump assembly on a cement truck. The hose attached to the pumper blew off and a stream of soft, liquid cement struck Employee #1 on the side of the head. The loose coupling and the unclean seating surfaces contributed to the failure of the hose connection.

Keywords: HEAD, CONCRETE TRUCK, INADEQUATE MAINT, UNSECURED, CONSTRUCTION, HOSE, STRUCK BY

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112112362 Non Hospitalized injury Fracture Concrete and terrazzo finishers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.