Accident Summary Nr: 170152649 - Employee injured when struck by falling storm drain pipe

Accident Summary Nr: 170152649 -- Report ID: 0950645 -- Event Date: 08/12/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
11221972008/17/199216230Blois Construction Co.

Abstract: Employee #1 was laying storm drain corrugated pipe in 20 ft lengths. The approximately 720 lb pipe was suspended on a lift by an all-nylon sling, type EE2 602, 12 ft long, hung on the hook of a backhoe in a choke hitch configuration. Employee #1 was in a trench 5 ft 6 in. deep under the load. The sling rated in this hitch configuration was 3,800 lb. The sling broke 3 ft from the hook and the pipe fell on Employee #1, breaking his leg and left wrist. Severe deterioration of the sling was evident. Employee #1 was transported to St. John's Hospital, where he was hospitalized. The Ventura Fire Department was on site.

Keywords: FRACTURE, INADEQUATE MAINT, DRAIN PIPE, WORK RULES, CONSTRUCTION, EQUIPMENT FAILURE, STRUCK BY, SLING, FALLING OBJECT, LEG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112219720 Hospitalized injury Fracture Construction laborers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close