Accident Summary Nr: 170151377 - Employee's hand crushed by press brake

Accident Summary Nr: 170151377 -- Report ID: 0950643 -- Event Date: 08/29/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
12008050209/08/199535810National Newsvend

Abstract: Employee #1, of National Newsvend, was using a press brake with a special die to punch holes on a metal piece to create the coin mechanism for newspaper vending machines. She was using a foot-operated control. The die was set so that the point of operation being guarded by the die was below 1/4 in. Employee #1 was holding the metal piece with her left hand and placed her right hand above the die. She pressed the control and the ram came down approximately 6 to 7 in. and crushed her hand against the frame of the die. Employee #1 suffered a severely crushed hand that required two surgical operations to be repaired.

Keywords: DIE, PRESS BRAKE, WORK RULES, CRUSHED, POINT OF OPERATION, FOOT-POWERED PRESS, PRESS OPERATOR, HAND, UNGUARDED, RAM

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 120080502 Hospitalized injury Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close